Skip to contents

sim_correct() Converts the brightness temperature to land surface temperature of a single value, vector or matrix or SpatRaster object. It is basically Equation 3 from vignette("Background") in the form of an R-function. This function is intended to simulate the effects of the parameters on the output and doesn't process any positional information/metadata.

Usage

sim_correct(
  T_bright,
  flight_height = 50,
  T_air = 25,
  rel_hum = 70,
  T_bg = NA,
  emiss = 0.985
)

Arguments

T_bright

Brightness temperature (in Kelvin) that you want to convert. This can either be a single value, a vector or a matrix or SpatRaster object

flight_height

(numerical) the height between the camera and the OBJECT OF INTEREST. Default is 50 m

T_air

(numerical) the air temperature in deg C during the flight. Default is 25 deg C

rel_hum

(numerical) the relative humidity in % during the flight. Default is 70 %

T_bg

(numerical) the background temperature in Kelvin, temperature measured from the aluminium panel. If not recorded set to NA and the parameter will not be accounted for.

emiss

(numerical) the emissivity, here by default an average for plants is given (0.985)

Value

Corrected LST in the same format as the T_bright parameter